All tests are to be conducted under the rules in force
following best practice procedures. In the UK these are
the procedures laid down by CORGI and the Gas Safety
and use Regulations.
1. ELECTRICAL TESTS
Electrical warning
THIS APPLIANCE IS SUPPLIED IN COMPONENT AND
SUB- ASSEMBLY FORM. WHILST THE SUB-ASSEMBLIES
THEMSELVES HAVE BEEN TESTED FOR ELECTRICAL
SAFETY AT REDFYRE, IT IS ESSENTIAL THAT THE WHOLE
APPLIANCE IS TESTED WHEN IT IS FULLY ASSEMBLED.
THIS WORK CAN ONLY BE UNDERTAKEN BY A
SUITABLY QUALIFIED ELECTRICIAN TRAINED IN THE
USE OF SPECIALISED EQUIPMENT. THE TEST MUST
INCLUDE;
• EARTHBONDCONTINUITY
• INSULATIONRESISTANCECHECK
• ELECTRICALINSULATIONFLASHTEST
IMPORTANT
IF THERE IS NO MAINS SUPPLY OR THE ABOVE TESTS
CANNOT BE CARRIED OUT, ENSURE THAT A WARNING
LABEL IS ATTACHED TO THE APPLIANCE STATING
THAT IT SHOULD NOT BE USED UNTIL ELECTRICALLY
TESTED BY A SUITABLY QUALIFIED ELECTRICIAN AND
INFORM THE CUSTOMER.
2. PRESSURE TEST
• Purgethegassupplytoexpelanydebristhatmayblock
the gas control.
• Connectasuitablepressuregaugetotheinletpressure
test point located on the isolation device and turn the gas
supply on. Light the burner and check all gas joints for
possible leaks. Turn the burner onto maximum and check
that the supply pressure is as stated on the data badge. Turn
the gas off and replace the test point screw.
• Checkthesepressuresareunaffectedbyothergas
appliances being used on the property.
• Checkthepressuretestpointforleaks.
3. SPILLAGE CHECK
• Closealldoorsandwindowsintheroom.Lightthe
burner and operate on maximum for 5 minutes.
• Positionalightedsmokematchjustinsidethedraught
divert hood to ensure all smoke is drawn in. If in doubt, run
the burner for a further 10 minutes and repeat the test.
• Repeatthetestwithanyextractorfansrunningon
maximum in the room or adjacent rooms and keep
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE COOKER AND
SEEK EXPERT ADVICE.
4. GAS RATE
• Checkthegasrate(naturalgasmodelsonly).
5. FUNCTIONAL CHECK
5.1 Check the general function of the cooker:
– Ignition
– Cross lighting
– Valve operation
– Thermostat operation
– Flame failure device
NOTE: THE COOKER WILL TAKE SEVERAL HOURS TO
REACH FULL OPERATING TEMPERATURE. FURTHER
ADJUSTMENT OF THE THERMOSTATIC GAS CONTROL
MAY BE REQUIRED TO SET THE OVEN TO THE DESIRED
OPERATING TEMPERATURE.